Standard Controller
Our extensive line of standard controllers satisfies most customer requirements. Based on the specific furnace model, the controller regulates the furnace temperature reliably. The standard controllers are developed and fabricated within the Nabertherm group. When developing controllers, our focus is on ease of use. From a technical standpoint, these devices are custom-fit for each furnace model or the associated application. From the simple controller with an adjustable temperature to the control unit with freely configurable control parameters, stored programs, PID microprocessor control with self-diagnosis system and a computer interface, we have a solution to meet your requirements.
![]() |
![]() |
![]() |
|
| B 130 | C 280 | C 290 | |
![]() |
![]() |
![]() |
|
| C 295 | B 150 | C 250 | |
![]() |
![]() |
![]() |
|
| H 100 | C 40/C 42 | B 170 | |
![]() |
|||
| P 320 | |||
| P 320 |
| B 130 | C 280 | C 290 | C 295 | R 6 | B 150 | C 250 | H 100 | C 40 | C 42 | B 170 | P 320 | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of programs | 2 | 9 | 9 | 9 | 1 | 1 | 9 | 9 | 9 | 9 | 1 | 9 |
| Steps per program¹ | 3 | 3 | 40 | 40 | 1 | 2 | 12 | 20 | 18 | 18 | 2 | 8 |
| Extra functions (e.g. fan or autom. flaps) | 2 | 2* | 2 | 2 | 2 | 2 | 2 | 2 | ||||
| Clear, blue-white LCD display | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | ||
| Graphic color display | √ | |||||||||||
| Status messages in clear text | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | |
| Start time configurable (e.g. to use night power rates) | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | |
| Power usage measurement | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | ||
| Operating hour counter | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | ||
| Auto tune | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | |
| Program entry in steps of 1 °C or 1 min. | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | |
| Keypad lock | √ | √ | √ | |||||||||
| Skip-button for segment jump | √ | √ | ||||||||||
| Drive of manual zone regulation | √ | √ | ||||||||||
| Interface for MV software | ● | ● | ● | ● | ● | ● | √ | ● | ● | ● | √ | |
| Programmable power outlet | ² | |||||||||||
| kWh meter | √ | √ | √ | √ | ||||||||
| Real-time clock | √ | √ | √ | |||||||||
| Maximum number of control zones | 1 | 1 | 1 | 1** | 1 | 1 | ||||||
| Bath control/Cascade control | ● | |||||||||||
| √ Standard l Option ¹ steps equal to one ramp-soak pair ² not for model L(T)15.. * Only one event relay is available on air circulation furnaces ** Control of additional separate slave regulators possible | ||||||||||||